• High Sensitivity HCG Pregnancy/New Virus/ HCV/ Malaria/ HIV Test Uncut Sheet
  • High Sensitivity HCG Pregnancy/New Virus/ HCV/ Malaria/ HIV Test Uncut Sheet
  • High Sensitivity HCG Pregnancy/New Virus/ HCV/ Malaria/ HIV Test Uncut Sheet
  • High Sensitivity HCG Pregnancy/New Virus/ HCV/ Malaria/ HIV Test Uncut Sheet
  • High Sensitivity HCG Pregnancy/New Virus/ HCV/ Malaria/ HIV Test Uncut Sheet
  • High Sensitivity HCG Pregnancy/New Virus/ HCV/ Malaria/ HIV Test Uncut Sheet

High Sensitivity HCG Pregnancy/New Virus/ HCV/ Malaria/ HIV Test Uncut Sheet

Type: Test Strips & Test Tube
Material: Plastic
Ethylene Oxide Sterilization: Without Ethylene Oxide Sterilization
Quality Guarantee Period: Two Years
Group: Anyone in Need.
Logo Printing: Without Logo Printing
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Transport Package
Carton
Specification
Strip/Cassette/Cup
Trademark
OEM
Origin
China
HS Code
3002190090
Production Capacity
50000000PCS/Year

Product Description

Different Uncut Sheet for In Virtro Diagnostic Tests
 

We are providing instant drug tests: strips, dipcards (multi-panel, up to 12), cassettes (up to 11), and cups

We can bring you high quality product at very aggressive pricing. We can make strips, dipcards (multi-panel up to 12), cassettes (up to 11), cups, and split cups (up to 10). With or without validity tests. We do specialize in custom manufacturing and private labeling, for small and big runs.

For Strip
 

Remove the test strip from the sealed pouch and use it as soon as possible.

  1. Immerse the strip vertically into the urine specimen with the arrow end pointing towards the urine. Do not immerse the strip past the Max Line. See the illustration below.
  2. Remove the strip after 10 seconds and lay the strip flat on a clean, dry, non-absorbent surface, and then begin timing.
  3. Wait for colored lines to appear. Interpret the test results at 3-5 minutes. Do not read results after 10 minutes

For Cassette

  1. Remove the test cassette from the sealed pouch.
  2. Hold the dropper vertically and transfer 3 full drops (approx. 100ml) of urine to the specimen well of the test cassette, and then begin timing. See the illustration below.
  3. Wait for colored lines to appear. Interpret the test results at 3-5 minutes. Do not read results after 10 minutes.

For Dipcard

       1. Remove the test card from the sealed pouch and use it as soon as possible.
       2. 
Remove the cap from the end of the test card. Immerse the strip(s) of the test card vertically in the urine specimen with arrows pointing toward the urine specimen. Immerse the test card to at least the level of the wavy lines on the strip(s), but not above the arrow(s) on the test card. See the illustration below.
       3. Remove the test card after 10 seconds and lay the card flat on a non-absorbent surface, and then begin timing.
       4. Wait for colored lines to appear. Interpret the test results at 3-5 minutes. Do not read results after 10 mins

For Multi-Drug Screen Test Cup

  1. Remove the test cup from the sealed pouch and use it as soon as possible.
  2. Donor provides specimen and secures the cap by pressing down on all three corners.
  3. On a flat surface, technician pushes key to a fully closed position.
  4. Peel off the label on the multi-drug test card to view results. The test is read in the reaction well.
  5. Start the timer and wait for colored lines to appear. Interpret the test results at 3-5 minutes. Results remain stable for up to sixty minutes. See the illustration below. For detailed operation instructions, please refer to the Procedure Card

Results Interpretation: Negative or Positive Indication

Negative:Two lines appear. One red line should be in the control region (C), and another apparent red or pink line adjacent should be in the test region (T). This negative result indicates that the drug concentration is below the detectable level. (*Note: The shade of red in the test line region (T) will vary, but it should be considered negative whenever there is even a faint pink line.)

Positive:One red line appears in the control region (C). No line appears in the test region (T). This positive result indicates that the drug concentration is above the detectable level.

 

Invalid:Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test using a new test panel. If the problem persists, discontinue using the lot immediately and contact your local distributor

High Sensitivity HCG Pregnancy/New Virus/ HCV/ Malaria/ HIV Test Uncut Sheet
High Sensitivity HCG Pregnancy/New Virus/ HCV/ Malaria/ HIV Test Uncut Sheet
High Sensitivity HCG Pregnancy/New Virus/ HCV/ Malaria/ HIV Test Uncut Sheet



High Sensitivity HCG Pregnancy/New Virus/ HCV/ Malaria/ HIV Test Uncut Sheet
High Sensitivity HCG Pregnancy/New Virus/ HCV/ Malaria/ HIV Test Uncut Sheet
High Sensitivity HCG Pregnancy/New Virus/ HCV/ Malaria/ HIV Test Uncut Sheet

High Sensitivity HCG Pregnancy/New Virus/ HCV/ Malaria/ HIV Test Uncut Sheet
 




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now