Basic Info.
Classification
Biological Diagnostics
Certification
CE, FDA, ISO13485, SGS
Group
Middle-aged and Old
Transport Package
Individual Foil Pouch/ Customized Package
Specification
Customized Package
Product Description
Digital Blood Pressure Monitor Upper arm/Blood Pressuremonitor for home/hospital
1.Product descriptionA wrist watch blood pressure monitor, also known as a blood pressure meter,sphygmomanometer , or blood pressure gauge, is a device used to measure blood pressure, composed of an inflatable cuff to collapse and then release the artery under the cuff in a controlled manner, and a mercury or mechanical manometer to measure the pressure. It is always used in conjunction with a means to determine at what pressure blood flow is just starting, and at what pressure it is unimpeded.- Irregular Heart Beat Detection
- WHO Classification Indicator
- 4*AA batteries&AC adapter power supply
- Large LCD,Time&Date display
- Last three times result average function
- 2*90 group memories storage
Item | Description |
Product Size | 130×100×47mm (L*W*H) |
LCD Size | 76×60mm |
Storage Condition | Temperature: -20°C~+55°C Humidility: < 85% |
Working Condition | Temperature: 5°C~40°C Humidility: < 85% |
Battery Life | 300 times |
Auto power off | Yes |
Low Voltage Display | Battery symbol |
Time & Date Display &Alarm clock | Yes |
Memory Storage | 2 x 90 sets (dual user mode) |
Inflation | Automatic inflation |
Accuracy | ±3mmHg/±0.4kpa (Pressure); ±5% (Pulse) |
BP Measure Range | 0~299mmHg |
Pulse Measure Range | 40 to 199 beats/min |
Battery | 4*AA (DC6V) |
Method | Oscillometric Measurement |
Weight | 352g with battery |
2.Feature
- 1. 100mm×68 mm Digital LCD display
2. Maximum 60 records per each user
3. 3rd technonoly: Measuring during inflation
(The updated technology in the world)
4. Wirelessly sync your data to the APP
5. Track your history and detect any changes over time
6. Detects irregular heartbeat
7. 2 Users memory
8. Average last 3 measurements
9. WHO classification indicator After service:
1.Service tenet: quick and decisive and thoughtful thorough and accurate;
2.Service objectives: service quality to win customer satisfaction;
3.Service efficiency: We will have a dedicated staff to detect problems with the product for testingf if you are not satisfied when you receive your goods, and promptly get back to you within 24 hours.
4.Service principles: products in the course of product issues caused by improper operation, we will provide a solution.
3.More other products
HCG,LH,FSH,HIV,HBSAG,HCV,HBV, HEV,SYPLILIS,TB,HP,NGH,Chlamydia,Malaria,PSA,MORE rapid diagnostic products supplied
CEA,FOB,Dengue,Troponin I, Toxoplasma, Drug of Abuse test,saliva alcohol test and so on.
♦ Overview
♦ Detailed Images
♦ Certifications
FAQ
Q1: What's the method u use to do the test?
A: Colloidal Gold Method.
Q2: What's ur MOQ ?
A: Always, for strip format, the MOQ is 5000pcs. While for cassette format, MOQ is 2000pcs, same as midstream.
Q3: What's ur packing of the tests?
A: If u choose the low cost, we will suggest u the bulk packing to go. Which means 1 test in a single pouch, then 100/40 pouches in a plastic bag, 50 bags in a carton. If u need to sell in pharmacy/chain shop or some countries which have strict requirements about the packing, u can choose to pack in a box, like 100pcs in a box, or even 1 test in a single box.
Q4: What's the main differences when comparing products from different suppliers?
A: U can compare the mainly features of the test: Accuracy, Sensitivity, Specificity, and then the Price.
Q5: Some tests can be tested with serum/plasma or with whole blood, so what's the difference?
A: Well, if the specimen is whole blood, people will need buffer, lancet and alcohol swab to help the test. If they buy all the accessories, they can test very easily at home. But if the specimen is serum/plasma, it will need centrifuge to separate serum from whole blood first. This way, it's better to use at lab or hospital. And in some words, serum/plasma test will always give a more accurate results.
Q6: How can i distinguish a good test kit?
A: U can judge from the 4facts:Technical data: Such as the accuracy, specificity and sensitivity.
Pouch sealing: Tight enough. If the foil pouch is not sealed well, the humidity in circustance will destroy the reactivity of antibodies labeled on NC membrane. Shelf life will be shorten down.
Flow speed: The shorter the better?? NO!! The reaction of antibodies on NC membrane and antigens in specimen usually requires quite a while to work sufficiently. U can refer to the instruction for more accurate time.
Background: Good test usually gives clean background after running. If there are red smears in the reading window, it usually caused by bad colloidal gold technology or bad NC membrane. Sometimes, the defect caused false positive result in practice
Address:
2704, Block B, Tianrun, Mansion, Hi-Tech District, Weifang, Shandong
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Health & Medicine
Management System Certification:
ISO 9001, ISO 13485, FSC
Company Introduction:
Shandong Highplus Biotech Co., Ltd. is a professional company engaged in the products of in vitro diagnostic reagents and related POCT analyzer products such as colloidal gold rapid detection reagents, Quantitative determination of chemiluminescent immunoassay reagent and bioactive materials.
More than 100 products in 9 series have been successfully developed and currently marketed, including but not limited to: Pregnancy test, DOA tests, infectious disease tests, tumor markers tests, cardiac markers tests, food safety tests, biochemical reagent series, allergy tests, integration of instruments and reagents.
As a rapid diagnostic supplier, we treat quality as life, with certifications of CE, ISO 9001, ISO 13485, CFDA, FDA and Free Sale Certificates for most of the products.
OUR MISSION: Provide consistent quality IVD products to care human health
OUR VISION: To be a leading provider of IVD health care products.